- A worker scope whose `systemctl --user stop` fails (a detached child ignoring SIGTERM) is SIGKILLed through systemd and re-stopped; a scope still not stopped is reported, so the force stop raises StopUnsettled naming it and the update aborts before the checkout moves, instead of counting the sweep as clean. - processes.json is shared by every interpreter on the home (an ACP editor's background commands too). Each checkpoint entry now records `owner_pid` (the writing gateway; a managed worker's jobs record its owner), and the sweep stops only entries owned by the killed gateway PID. Entries without the field (older writers) are skipped and reported, never killed. - _abort_unsettled persists `stop_unsettled` on each systemd unit in the pause record. Recovery's split_draining holds such a unit while systemd still reports it deactivating or with a pending job (unreadable counts as pending), and the next `hermes update --force` refuses before the checkout moves while an adopted unit is still stopping (discovery skips it: MainPID 0).
221 lines
12 KiB
Python
221 lines
12 KiB
Python
"""``hermes update --force`` stops the update's gateways at once instead of draining them."""
|
|
|
|
import json
|
|
import signal
|
|
import subprocess
|
|
import sys
|
|
import time
|
|
|
|
import pytest
|
|
|
|
from hermes_cli import update_cmd_force_stop as force_stop
|
|
from hermes_cli import update_cmd_posix_pause as posix_pause
|
|
|
|
pytestmark = pytest.mark.platforms("posix")
|
|
|
|
|
|
def _child(ignore_term: bool) -> subprocess.Popen:
|
|
code = ("import signal, time\n"
|
|
+ ("signal.signal(signal.SIGTERM, signal.SIG_IGN)\n" if ignore_term else "")
|
|
+ "print('ready', flush=True)\n"
|
|
+ "time.sleep(600)\n")
|
|
proc = subprocess.Popen([sys.executable, "-c", code], stdout=subprocess.PIPE, text=True)
|
|
assert proc.stdout.readline().strip() == "ready" # the SIGTERM disposition is set
|
|
return proc
|
|
|
|
|
|
@pytest.fixture
|
|
def no_record(monkeypatch):
|
|
from hermes_cli import update_pause_record
|
|
monkeypatch.setattr(update_pause_record, "mark_stop_sent", lambda token, pid: None)
|
|
|
|
|
|
def test_force_pause_never_asks_for_a_drain_and_stops_within_the_bound(monkeypatch, tmp_path, no_record):
|
|
"""A live gateway that ignores SIGTERM (a turn the drain would wait 30 min on) is gone within
|
|
the force bound, and the drain request is never sent."""
|
|
proc = _child(ignore_term=True)
|
|
try:
|
|
monkeypatch.setattr(force_stop, "FORCE_KILL_AFTER_S", 1.0)
|
|
monkeypatch.setattr(posix_pause, "_ask_to_drain",
|
|
lambda entry: pytest.fail("--force must not request a drain"))
|
|
monkeypatch.setattr(posix_pause, "_drain_budget", lambda: 1800.0)
|
|
entry = {"pid": proc.pid, "home": str(tmp_path), "argv": ["x"], "ct": None}
|
|
started = time.monotonic()
|
|
posix_pause._stop_gateways({"force": True}, [entry])
|
|
assert time.monotonic() - started < 10.0
|
|
assert proc.wait(timeout=5) == -signal.SIGKILL
|
|
finally:
|
|
if proc.poll() is None:
|
|
proc.kill()
|
|
|
|
|
|
def test_force_stop_names_what_it_interrupted(monkeypatch, tmp_path, capsys, no_record):
|
|
proc = _child(ignore_term=False)
|
|
try:
|
|
monkeypatch.setattr(force_stop, "_live_work", lambda entry: [
|
|
{"kind": "chat", "session": "agent:main:api_server:dm:s1", "current_tool": "terminal"},
|
|
{"kind": "delegation", "delegation_id": "deleg_1", "goal": "child"}])
|
|
force_stop.force_stop_gateways({}, [{"pid": proc.pid, "home": str(tmp_path), "ct": None}])
|
|
assert proc.wait(timeout=5) == -signal.SIGTERM
|
|
out = capsys.readouterr().out
|
|
assert f"gateway PID {proc.pid}: stopped by --force, interrupting 2 unit(s)" in out
|
|
assert "background delegation deleg_1" in out
|
|
finally:
|
|
if proc.poll() is None:
|
|
proc.kill()
|
|
|
|
|
|
def test_force_kills_the_unit_when_its_stop_job_outlives_the_gateway(monkeypatch, tmp_path, no_record):
|
|
"""The gateway exits but its unit's stop job hangs on another process: the force deadline
|
|
still kills the unit and waits for the job, instead of reporting failure (and rolling back)."""
|
|
import threading
|
|
released, kills = threading.Event(), []
|
|
monkeypatch.setattr(force_stop, "FORCE_KILL_AFTER_S", 0.5)
|
|
monkeypatch.setattr(force_stop, "_live_work", lambda entry: [])
|
|
monkeypatch.setattr(posix_pause, "_stop_at_once", lambda entry: released.wait(10))
|
|
monkeypatch.setattr(force_stop, "_kill", lambda entry: (kills.append(entry["unit"]), released.set()))
|
|
gone = {"pid": 2 ** 22 + 7, "home": str(tmp_path), "ct": None, "kind": "systemd", "scope": "user",
|
|
"unit": "hermes-gateway.service"}
|
|
force_stop.force_stop_gateways({}, [gone])
|
|
assert kills == ["hermes-gateway.service"]
|
|
|
|
|
|
def _sleeper() -> subprocess.Popen:
|
|
"""A background tool process the gateway left behind: its own session, as a scope would be."""
|
|
return subprocess.Popen([sys.executable, "-c", "import time; time.sleep(600)"],
|
|
stdin=subprocess.DEVNULL, start_new_session=True)
|
|
|
|
|
|
def test_force_sweeps_the_background_processes_a_killed_gateway_left_behind(monkeypatch, tmp_path, capsys,
|
|
no_record):
|
|
"""A SIGKILLed gateway never runs ``process_registry.kill_all``: the processes its checkpoint
|
|
names are stopped for it, and a recorded PID now held by another process is never signalled."""
|
|
from gateway.status import get_process_start_time
|
|
from tests.waiting import wait_until
|
|
gateway, left, stranger = _child(ignore_term=True), _sleeper(), _sleeper()
|
|
try:
|
|
wait_until(lambda: get_process_start_time(left.pid) and get_process_start_time(stranger.pid))
|
|
(tmp_path / "processes.json").write_text(json.dumps([
|
|
{"session_id": "proc_left", "pid": left.pid, "pid_scope": "host", "systemd_unit": "",
|
|
"host_start_time": get_process_start_time(left.pid), "persist_on_release": True,
|
|
"owner_pid": gateway.pid,
|
|
"command": "sleep 900"},
|
|
{"session_id": "proc_recycled", "pid": stranger.pid, "pid_scope": "host", "systemd_unit": "",
|
|
"host_start_time": get_process_start_time(stranger.pid) + 1, "owner_pid": gateway.pid,
|
|
"command": "sleep 900"}]))
|
|
monkeypatch.setattr(force_stop, "FORCE_KILL_AFTER_S", 0.5)
|
|
monkeypatch.setattr(force_stop, "_live_work", lambda entry: [])
|
|
force_stop.force_stop_gateways({}, [{"pid": gateway.pid, "home": str(tmp_path), "ct": None}])
|
|
assert gateway.wait(timeout=5) == -signal.SIGKILL
|
|
wait_until(lambda: left.poll() is not None, timeout=10, what="the left-behind process to be stopped")
|
|
assert stranger.poll() is None, "a recycled PID (start time mismatch) was signalled"
|
|
assert f"gateway PID {gateway.pid}: also stopped 1 background process(es) it left behind" \
|
|
in capsys.readouterr().out
|
|
finally:
|
|
for proc in (gateway, left, stranger):
|
|
if proc.poll() is None:
|
|
proc.kill()
|
|
proc.wait(timeout=5)
|
|
|
|
|
|
def test_an_unsettled_force_stop_aborts_before_the_checkout_moves(monkeypatch, tmp_path, no_record):
|
|
"""The unit's stop job outlives the force deadline and its kill: nothing may be started behind
|
|
it, so the commit point refuses (no swap), nothing is resumed now, and the record stays owed."""
|
|
import threading
|
|
from hermes_cli import update_pause_record as pause_record
|
|
monkeypatch.setenv("HERMES_HOME", str(tmp_path))
|
|
released = threading.Event()
|
|
unit = {"kind": "systemd", "scope": "user", "unit": "hermes-gateway.service", "pid": 2 ** 22 + 9,
|
|
"home": str(tmp_path), "cgroup": None}
|
|
monkeypatch.setattr(posix_pause, "_discover_systemd", lambda: [dict(unit)])
|
|
monkeypatch.setattr(posix_pause, "_discover_launchd", list)
|
|
monkeypatch.setattr(posix_pause, "_left_running", lambda units, jobs: (units, jobs, []))
|
|
monkeypatch.setattr(posix_pause, "_discover_bare", lambda service_pids: ([], []))
|
|
monkeypatch.setattr(posix_pause, "_stop_at_once", lambda entry: released.wait(30))
|
|
monkeypatch.setattr(posix_pause, "resume_paused_set",
|
|
lambda token: pytest.fail("a start was queued behind a stop still running"))
|
|
monkeypatch.setattr(force_stop, "_kill", lambda entry: None)
|
|
monkeypatch.setattr(force_stop, "_live_work", lambda entry: [])
|
|
monkeypatch.setattr(force_stop, "FORCE_KILL_AFTER_S", 0.2)
|
|
monkeypatch.setattr(force_stop, "_STOP_JOB_SETTLE_S", 0.2)
|
|
token = {**posix_pause._empty_token(), "force": True}
|
|
monkeypatch.setattr(posix_pause, "_RUN", token)
|
|
try:
|
|
refused = posix_pause.pause_at_commit_point()
|
|
finally:
|
|
released.set()
|
|
assert refused and "hermes-gateway.service" in refused, f"no refusal naming the unit: {refused!r}"
|
|
assert not token["resume_needed"], "this process would start the unit behind its stop job at exit"
|
|
owed = pause_record.read()
|
|
assert owed and owed["token"]["resume_needed"], "the stopped unit is no longer owed a restart"
|
|
assert [u["unit"] for u in owed["token"]["posix_units"]] == ["hermes-gateway.service"]
|
|
|
|
|
|
def test_the_sweep_never_touches_a_process_another_interpreter_recorded(monkeypatch, tmp_path, no_record):
|
|
"""``processes.json`` is shared by every interpreter on the home (an ACP editor's background
|
|
commands too): the sweep stops only what the killed gateway recorded, never another's job."""
|
|
import os
|
|
from gateway.status import get_process_start_time
|
|
from tests.waiting import wait_until
|
|
gateway, foreign = _child(ignore_term=True), _sleeper()
|
|
try:
|
|
wait_until(lambda: get_process_start_time(foreign.pid))
|
|
(tmp_path / "processes.json").write_text(json.dumps([
|
|
{"session_id": "proc_acp", "pid": foreign.pid, "pid_scope": "host", "systemd_unit": "",
|
|
"host_start_time": get_process_start_time(foreign.pid), "owner_pid": os.getpid(),
|
|
"command": "npm run dev"}]))
|
|
monkeypatch.setattr(force_stop, "FORCE_KILL_AFTER_S", 0.5)
|
|
monkeypatch.setattr(force_stop, "_live_work", lambda entry: [])
|
|
force_stop.force_stop_gateways({}, [{"pid": gateway.pid, "home": str(tmp_path), "ct": None}])
|
|
assert gateway.wait(timeout=5) == -signal.SIGKILL
|
|
assert foreign.poll() is None, "the sweep killed a background process the gateway did not own"
|
|
finally:
|
|
for proc in (gateway, foreign):
|
|
if proc.poll() is None:
|
|
proc.kill()
|
|
proc.wait(timeout=5)
|
|
|
|
|
|
def test_a_worker_scope_that_will_not_stop_aborts_the_update(monkeypatch, tmp_path, no_record):
|
|
"""The killed gateway's worker scope holds a child ignoring SIGTERM and its stop fails even
|
|
after the scope is SIGKILLed: that is an unsettled stop naming the scope, never a clean sweep."""
|
|
from tools import process_registry
|
|
gateway, killed = _child(ignore_term=True), []
|
|
try:
|
|
(tmp_path / "processes.json").write_text(json.dumps([
|
|
{"session_id": "proc_w", "pid": None, "pid_scope": "host", "host_start_time": None,
|
|
"systemd_unit": "hermes-worker-proc_w.scope", "owner_pid": gateway.pid, "command": "x"}]))
|
|
monkeypatch.setattr(process_registry, "_stop_systemd_unit", lambda unit: False)
|
|
monkeypatch.setattr(force_stop, "_kill_scope", killed.append, raising=False)
|
|
monkeypatch.setattr(force_stop, "FORCE_KILL_AFTER_S", 0.5)
|
|
monkeypatch.setattr(force_stop, "_live_work", lambda entry: [])
|
|
with pytest.raises(posix_pause.StopUnsettled, match="hermes-worker-proc_w.scope"):
|
|
force_stop.force_stop_gateways({}, [{"pid": gateway.pid, "home": str(tmp_path), "ct": None}])
|
|
assert killed == ["hermes-worker-proc_w.scope"], "the scope was not SIGKILLed before giving up"
|
|
finally:
|
|
if gateway.poll() is None:
|
|
gateway.kill()
|
|
gateway.wait(timeout=5)
|
|
|
|
|
|
def test_recovery_never_starts_a_unit_whose_force_stop_is_still_running(monkeypatch, tmp_path):
|
|
"""An aborted ``--force`` left the unit's stop job running after its gateway PID exited: the
|
|
next launch's recovery holds the unit (still owed) instead of queueing a start behind it."""
|
|
from hermes_cli import update_cmd_fleet_unit_budget as budget
|
|
from hermes_cli import update_pause_record as pause_record
|
|
monkeypatch.setenv("HERMES_HOME", str(tmp_path))
|
|
unit = {"kind": "systemd", "scope": "user", "unit": "hermes-gateway.service", "pid": 2 ** 22 + 11,
|
|
"home": str(tmp_path), "ct": None}
|
|
token = pause_record.record_pause({**posix_pause._empty_token(), "resume_needed": True,
|
|
"posix_units": [unit], "identities": {}}, None, [])
|
|
posix_pause._abort_unsettled(token, "systemd's stop job for hermes-gateway.service is still stopping")
|
|
body = pause_record.read()
|
|
pause_record._atomic_write(pause_record.record_path(), {**body, "owner": pause_record.UNOWNED}) # updater exited
|
|
monkeypatch.setattr(budget, "unit_job_state",
|
|
lambda scope, name: {"ActiveState": "deactivating", "SubState": "stop-sigterm", "Job": "42"})
|
|
monkeypatch.setattr(posix_pause, "_start_unit", lambda entry: pytest.fail("started behind its stop job"))
|
|
pause_record.recover(["status"])
|
|
[claim] = pause_record._claims(pause_record.record_path())
|
|
owed = pause_record.read(claim)["token"]
|
|
assert [u["unit"] for u in owed["posix_units"]] == ["hermes-gateway.service"], "the unit's restart was dropped"
|